  80 0 ~ 150psi (0 ~ 1mpa) 0 ~ -30in. hg (-100 ~ 0kpa) 89 ~ -30in. hg (-100 ~ 300kpa) -4 ~ 158f (-20 ~ 70c) (atomospheric pressure, hummidity less than 60%rh) 32 ~ 140f (0 ~ 60c) (no freezing) 35 ~ 85%rh (no freezing) iec standard ip40 equiv. 1 npn open collector output: 30v 80ma max. residual voltage 0.8v max. n.o. (red led lights up when set pressure exceeded) fixed (2%f.s. max.) 3%f.s. max. (at ta=25c/77f) approx. 1msec 0 ~ 150psi (0 ~ 1mpa) 218psi (1.5mpa) 0 ~ -30in. hg (-100 ~ 0kpa) 29psi (200kpa) 89 ~ -30in. hg (-100 ~ 300kpa) 87psi (600kpa) air, inert gas proliferated semiconductor pressure switch dc10.8 ~ 30v (ripples included) 20ma or less (dc24v at no-load) seu 11 series vus 11 series vus 11-r series sensor heads, separate display type pressure sensor and vacuum switch small-sized 24.5-mm pressure sensors (width: 10mm height, 10mm total length). "union," "nipple," and "male screw" are prepared. use of an analog output type and indicator (sed30-series) has made a separate display system possible. our small-sized pressure sensors can handle "positive pressure," "negative pressure" and "compound pressure". concerning output, a total of six different specifications are prepared. standard cable length is 3m. a large 31.4mm square size indicator is used, realizing a high level of visibility with its large-sized led display. all settings can be made using just three push buttons. for indication units, you can choose from among 11 different types. two different kinds of output methods are offered - analog output and switch output. four (4) different kinds of installation stays are available depending on installation form. - for installation in the rear, on a flat surface, panel-buried, and for protection of display components. specification fluid admitted pressure detection power requirements power consumption service pressure range proof pressure storage temperature range operating temperature range operating hummidity range protective structure no. of pressure setting switch output display of action switch output differential response operating accuracy response pressure setting range -4 ~ 158f (-20 ~ 70c) (atomospheric pressure, hummidity less than 60%rh) 32 ~ 140f (0 ~ 60c) (no freezing) 35 ~ 85%rh (no freezing) iec standard ip40 equiv. 1 ~ 5v 1 0.1v 5 0.1v 1ma max. (load resistance 5k ? min.) 0.5%f.s. max. 0 ~ 150psi (0 ~ 1mpa) 218psi (1.5mpa) 0 ~ -30in. hg (-100 ~ 0kpa) 29psi (200kpa) 89 ~ -30in. hg (-100 ~ 300kpa) 87psi (600kpa) air, inert gas proliferated semiconductor pressure switch dc10.8 ~ 30v (ripples included) 20ma or less (dc24v at no-load) seu 11 series vus 11 series vus 11-r series specification fluid admitted pressure detection power requirements power consumption service pressure range proof pressure storage temperature range operating temperature range operating hummidity range protective structure output voltage zero-point voltage analog output max. rated pressure voltage output current linearity
81 1 digit 3-digit 7-segmented led (character height: 8mm), colored red led lamp (illuminates at "minus", colored red) pressure indication units and rated pressure ranges are selected via the panel switches listed in the table given below. 2-point outputs (sw1, sw2) npn open collector dc30v 100ma max. 1.2v max. (with load current at 100ma) using a panel switch -999 ~ 999 count (decimal points are to conform to the range of rated voltage as given in the tabulated specifications). two leds light up (sw1: green, sw2: red, when output is switched on) 0.2%f.s. 1count 0.5f.s. (32 ~ 122f (0 ~ 50c), reference temperature: 25c/77f) can be adjusted by setting digital filters, 5, 25, 250, 2500msec 0 ~ 300 counts (canbe adjusted via a panel switch) 2-point output switches (sw1, sw2) are switched off (overload current: "200ma or beyond" or "beyond 200ma") 1 ~ 5v 1ma (load resistance: 5k ? min.) 1 0.1 ~ 5 0.1v before using the pisco device, be sure to read the "safety instructions", "common safety instructions for products listed in this manual" on page 15 to 17 and "common safety instructions for control series" on page 59 and "common safety instructions for led digital pressure sensors, digital pressur sensors & pressure sensors" on page 77. positive pressure sensor negative pressure sensor ?4mm nipple ?6mm nipple m5 0.8 male screw r1/8 male screw ?4mm quick-fitting joint (fitted with an in-line installation holder) ?6mm quick-fitting joint (fitted with an in-line installation holder) analog output compound pressure type analog output npn open collector output compound pressure type npn open collector output * compound pressure type ( r) is only accepted when "VUS11" is selected. rear angles (rear angles, two m3 4 male screws) flat surface angles (two m3 4 male screws) holder cover set (a panel holder cover, a panel holder) panel holder set (a panel cover, a panel holder and panel stopper) holder stopper set (a panel holder and panel stopper) ? 1. for power, use stable direct currents. 2. insert surge-absorbing circuits into relays, valves, etc. do not arbitrarily use these units at currents that exceed rated levels. 3. when using unit power sources, such as switching power sources, be sure to ground their fg terminals. 4. take the utmost care to avoid short-circuitting the output terminal with other terminals. 5. do not apply excessive loads to pressure sensors. subjecting them to excessive loads can damage them. 6. do not wire nozzles and other components in a way that will impress them with noises, etc. do not use them in any arbitrary manner, either. doing so can cause malfunctions. 7. when conducting pressure adjustments for units fitted with switch output sensors, use small screwdrivers (included). do not apply excessive force to these screwdrivers, and turn them slowly. applying excessive force may damage the units. 8. our indicator (sed-30) is not constructed to be drip- or dust-proof. as such, do not use indicators that have been exposed to water or oil and/or dust. 9. for the sed-30 indicator?s sensor heads, use either a ?vus 11?a.? or an ?seu 11?a? type head. using different specifications with these sensor heads will not achieve the required level of accuracy. 10. do not pull or bend vacuum switch lead wires excessively. doing so may result in lead wires being snapped off and connector components broken. sed-30 dc10.8 ~ 30v 50ma max. (supply voltage: dc10bv when a 2-point switch is turned on for output) -4 ~ 158f (-20 ~ 70c) (atomospheric pressure, hummidity less than 60%rh) 32 ~ 122f (0 ~ 50c) (no freezing) 35 ~ 85%rh (no freezing) iec standard ip40 equiv. 4 times/sec variable with a digital filter, about 5, 25, 250, 2500msec 1%f.s. 0.5f.s. (32 ~ 122f (0 ~ 50c), reference temperature: 25c/77f) beyond indicated numbers of digits beyond detection range detection of output overloads monitoring of adjustment errore "9 9 9" flashes "- - -" flashes (rated pressure: 110% or more) "e - 1" flashes/overloads detected, output indication lamp flashes panel switch-operated pressure indication (zero clear) monitors "0" adjustment operation when residual pressure is impressed beyond (10%f.s.). "error warning e-2" flashes (cancelled using a panel switch) specification power requirements consumption current storage temperature range operating temperature range operating hummidity range protective structure no. of indications response indication accuracy temperature characteristics monitoring function pressure indication method "0" adjustment function resolution pressure indication element code indication element rated pressure indication range number of output point switch output method switch capacity residual voltage pressure setting method switch output pressure setting range operational indication repetitiveness temperature characteristics response setting differential responses protection against overloads analog output output voltage output current sensor input specifications voltage input signal kpa VUS11- a -12p 0.0 ~ -99.9 0.00 ~ -1.02 0 ~ (-999) 0 ~ -750 ? 0.00 ~ -1.02 0 ~ -999 0.0 ~ -14.5 ? ? 0.0 ~ -29.5 3 32r -100 ~ 300 -1.02 ~ 3.06 ? ? ? -1.00 ~ 3.00 ? -14.5 ~ 43.5 ? -0.10 ~ 0.30 -29.5 ~ -88.5 1 13p 0 ~ 999 0.00 ~ (9.99) ? ? ? 0.0 ~ 9.99 ? 0 ~ 145 ? 0.00 ~ 1.00 0 ~ 295 2 VUS11- ar seu11- a pressure sensors used units of pressure magnification (unit) pressure range setting code 1 (kpa) 0.0102 (kgf/cm 2 ) 10.2 (gf/cm 2 ) 7.501 (mmhg) 102 (mmh 2 o) rated pressure 0.01 (bar) indication range 10 (mbar) (pl ~ ph) 0.145 (psi) 0.000145 (kpsi) 0.001 (mpa) 0.2953 (in.hg) analog output mode indicated
82 *it is equipped with two screws for fixing the sensor. model acpg-012 model acpg-011 *it is equipped with two screws for fixing the sensor. model acpg-007 model acpg-004 model seu11-m5s seu11-01s VUS11-m5s VUS11-01s VUS11-m5sr VUS11-01sr model seu11-4s seu11-6s VUS11-4s VUS11-6s VUS11-4sr VUS11-6sr model seu11-4us seu11-6us VUS11-4us VUS11-6us VUS11-4usr VUS11-6usr model seu11-m5a seu11-01a VUS11-m5a VUS11-01a VUS11-m5ar VUS11-01ar model seu11-4a seu11-6a VUS11-4a VUS11-6a VUS11-4ar VUS11-6ar model seu11-4ua seu11-6ua VUS11-4ua VUS11-6ua VUS11-4uar VUS11-6uar model sed-30 model acpg-003


▲Up To Search▲   

 
Price & Availability of VUS11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X